126. An incineration facility governed by this Chapter that has a rated capacity of less than 1 ton per hour must have at least 2 combustion chambers.
Gases from the primary combustion chamber must be brought to a temperature greater than 1,000°C for at least 1 second when they reach the final combustion chamber.
In addition, no residual materials may be fed into the primary combustion chamber during the preheating of the final combustion chamber, or be ignited until the temperature of the gases in the final combustion chamber has been maintained at a temperature of at least 1,000°C for a minimum of 15 minutes.
The facility must have auxiliary gas or liquid fossil fuel burners.